ENGINEERED FOR THE FACILITIES THAT CAN'T AFFORD TO STOP
The Coral JETCLEAN DF is a high-performance explosive dust collector designed for the safe extraction and filtration of non-conductive, non-metal combustible dust (ST1). Engineered to meet NFPA 660 compliance, it helps reduce risk, improve air quality, and maintain safe operating conditions in environments where combustible dust is present.
Ideal for industries such as food processing, pharmaceuticals, agriculture, and aerospace, this combustible dust extraction system captures hazardous particles at the source—protecting operators, equipment, and facilities.
Equipped with the EVOLUTION NO SMOKE ATEX Extraction Arm and a pneumatic filter cleaning system, the unit ensures consistent performance while minimizing electrical components in critical areas for enhanced safety.
JETCLEAN DF NFPA 660 isn’t a standard explosive dust collector—it’s purpose-built for ST1 combustible dust environments where safety can’t be compromised. Every design choice reduces risk: clean-side motor placement keeps critical components away from contaminated airflow, while anti-static construction and anti-spark protection actively minimize ignition sources.
The pneumatic cleaning system removes the need for electrical components in sensitive areas, creating a safer, more controlled solution aligned with NFPA 660 requirements—without overcomplicating the system.
Downtime kills productivity. JETCLEAN DF is designed to keep your operation moving with stable airflow, consistent filtration efficiency, and minimal maintenance intervention.
Self-maintaining filters, real-time performance monitoring, and effective source capture mean fewer interruptions, longer filter life, and predictable performance day after day. It’s not just dust collection—it’s reliability you can build your process around.
Same as the Jetclean DF: pre-chamber separation into the first bin, horizontal M-class cartridge, finest dust into the second bin, top-mounted fan on the clean side, outlet grille in the plenum, automatic compressed-air cleaning.
Available in NFPA-compliant version.
Self-cleaning extractor equipped with 1 horizontal cartridge filter, designed for the extraction and filtration of non-conductive, non-metallic explosive dust (ST1) in NFPA 652 compliant applications. Automatic cartridge cleaning by compressed air system.
Compared with the standard Jetclean DF, the scope moves from welding fumes, gases and vapors to ST1 explosive dust that is neither conductive nor metallic; the cartridge becomes anti-static, the fan is uprated and the front bin is smaller.
Explosive Dust Extraction and Filtration Process:
Hazardous dust and gases are captured directly at the source through the EVOLUTION NO SMOKE ATEX extraction arm, preventing exposure to the operator. The contaminated air enters the unit through the dirty air inlet, where heavier particles naturally separate from the airflow. The remaining fine dust passes through high-efficiency anti-static cartridge filters, removing up to 99% of airborne contaminants.
The airflow path is the same as on the Jetclean DF. NFPA-specific values:
Monitoring: differential pressure gauge, standard component.
Automatic compressed-air cleaning, as on every Jetclean DF, with an automatic compressed air cleaning tank. Pneumatic cleaning keeps electrical components out of the sensitive area: filter cleaning happens without introducing an ignition source where the combustible dust actually is.
For complete specifications, dimensions and options, see the Jetclean DF NFPA 660 Compliant technical sheet.
| Model | Arms | Arm length (ft) | Arm diameter (in) | Cartridges | Cartridge height (in) | Cartridge diameter (in) | Filter material | IFA/BGIA classification | Voltage (V) | Frequency (Hz) | Bins | Bin capacity (gal) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Jetclean DF1 NFPA 660 | 1 | 10 | 6.3 | 2 | 15.8 | 12.8 | Polyester | Anti-static PES | 120 | 60 | 2 | 2.4 + 3.2 |
| Model | Filter surface area (sq ft) | Max. flow rate (CFM) | Speed (rpm) | Power (HP) | Noise with soundproof plenum (dB) |
|---|---|---|---|---|---|
| Jetclean DF1 NFPA 660 | 86.1 | 950 | 3420 | 1.5 | 69 |
| Model | Length (in) | Height (in) | Width (in) | Weight (lb) |
|---|---|---|---|---|
| Jetclean DF1 NFPA 660 | 26.5 | 92.9 | 60.2 | 296 |
Our
Non-conductive, non-metal combustible dust in class ST1. It is designed for non-classified areas with controlled dust levels, and it is not a substitute for area classification.
Every difference reduces ignition risk. The motor and impeller sit in the clean area, the wheels and cartridges are anti-static, an anti-spark feature protects the fan inlet, and the dirty-side enclosure volume is held under 8 cubic feet.
The Evolution No-Smoke ATEX extraction arm, so the capture point is grounded and static dissipating from the hood back to the unit.
Pneumatic cleaning keeps electrical components out of the sensitive area. Filter cleaning happens without introducing an ignition source where the combustible dust actually is.
Food processing powders and ingredients, pharmaceutical material handling, agricultural processing of organic combustible material, and aerospace work involving non-metallic explosive dust.
Fill out the form below and write us about your filtration challenge. We’ll get back to you within 24h.