0%

CORAL

ENGINEERED FOR THE FACILITIES THAT CAN'T AFFORD TO STOP

Iperjet DF TOWER

Iperjet DF TOWER

Iperjet DF TOWER

Air Purification Tower

Horizontal cartridge filter unit, effective even in large space

Coral IPERJET DF TOWER Air Purification system is a horizontal cartridge filter unit for suction and filtration of welding and thermal cutting fumes, coarse and fine dusts. IPERJET DF TOWER is designed for applications where local capture of contamination is not possible or adequate and full room filtration is required. Those applications would include installations where the following situations occur.

  • Local/source exhaust is difficult or not possible.
  • Ductwork installation is complicated or not suitable.
  • Air-conditioned or heated spaces, where exhausting the conditioned air outdoor is not prudent and the need to recycle the indoor air is required to save energy costs.
  • Environments where the source of pollutant/smoke is changing depending on process.
  • Insufficient local exhaust performed by portable units or weak filtering capability of the existing pollution control systems.
Welding application

Welding

Thermal Cutting application

Thermal Cutting

Dry Dust application

Dry Dust

How can IPERJET DF TOWER benefit your business

  • Reduce energy costs, eliminate the need to exhaust plant climate-controlled air (up to 70% savings depending on location and climatic conditions).
  • Easy and low installations cost, no need for costly piping or duct work.
  • Easy to transportation and install, includes lifting eyelets and forklift lifting points.
  • Quick maintenance of the horizontal cartridges.
  • Stand-alone positioning and easy to move to another location when required.
  • Easy dust disposal from a container with wheels.
  • User friendly touchscreen panel control.
  • Plug & play installation with compressed air connection and electric power.
  • Quiet operation due to Coral’s high efficiency backward curved fans.
  • Layered ventilation zones that provide filtered air breathing zones for the employees.

How it Works

Operating Principle

Polluted and warm air rises and will be sucked in at the top inlet, filtered by the high efficiency Class M filter cartridges up to 99,9% of dust particles and returned in the workspace in the low outlets diffusers creating an up going clean air flow that benefits the workers (optional: HEPA H13 filters up to 99,95%).

The Coral IPERJET DF Air Purification Tower has been studied and designed for various applications in workshops where: Local/source exhaust is difficult or not possible; Ductwork installation is complicated or not suitable; Air-conditioned or heated workshops to avoid energy waste in exhausting the air outdoor and the need to recycle the outside air; Environments where the source of pollutant/smoke is changing depending on process; Production, assembling and logistic areas; Insufficient local exhaust performed by portable units or weak filtering capability of the existing pollution control system.

Unlike the Iperjet DF and MAX, the TOWER is not fed by arms or ducts. It is a free-standing room air cleaner that draws the rising fume layer in at roof level and returns filtered air at floor level, the CORAL IPERJET DF Push & Pull System, giving layered ventilation with a filtered air breathing zone for the workers. It shares the family’s horizontal class M cartridges and automatic compressed-air cleaning. Typical duty: welding smoke, smoke, fumes and dust particles.

Airflow Path

  • Top inlet(s) on the roof of the tower (polluted, warm air rising in the room)
  • Horizontal Class M cartridges (6 or 9); optional HEPA H13 stage
  • High efficiency low noise backward curved twin fans, speed-controlled by the optional inverter
  • Low outlet diffusers, slow air speed recirculation of the filtered air
  • Upward clean-air flow through the breathing zone back to the roof inlet

The tower carries a touchscreen control panel (ON/OFF), a compressed air inlet connection, the electric power line in and a cable connection for an optional sniffer probe.

Airflow: Tower 10000 10,000 m3/h (about 5,890 CFM), 2 x 3 kW, 2,890 rpm, 66 dB; Tower 15000 15,000 m3/h (about 8,830 CFM), 2 x 4 kW, 2,900 rpm, 68 dB; Tower 20000 20,000 m3/h (about 11,770 CFM), 2 x 5.5 kW, 2,910 rpm, 72 dB. Dimensions 1420 x 1980 x H 3360 mm (10000, 15000), 1950 x 2080 x H 3680 mm (20000); weight 1,200 / 1,400 / 1,500 kg. Power consumption less than 1.5 kW per 1,000 m3 of cleaned workshop air.

Filtration stages

  • Main stage – Horizontal cartridges, BGIA Class M-Cel 6066 cellulose tested long life filtering cartridges, Ø325 x H 1200 mm (about Ø12.8 x 47 in): Tower 10000 6 cartridges, 121 m2 (about 1,300 sq ft); Tower 15000 and 20000 9 cartridges, 181 m2 (about 1,950 sq ft). Efficiency up to 99.9% of dust particles.
  • Optional stage – HEPA H13 filters up to 99.95%.

Cleaning System

Built-in, fully automatic, energy-saving compressed air jet cleaning of the filter elements, as on the rest of the Iperjet DF family. Plug & play installation with just a compressed air connection and electric power, and quick maintenance of the horizontal cartridges.

For complete specifications, dimensions and options, see the Iperjet DF TOWER technical sheet.

Technical Table

Model Filter Cartridges (nr) Cartridge height (in) Cartridge diameter (in) Voltage (V) Frequency (Hz) Bin storage capacity (gal)
Iperjet DF TOWER 10000 Cartridges 6 47 13 230/460 60 16
Iperjet DF TOWER 15000 Cartridges 9 47 13 230/460 60 16
Iperjet DF TOWER 20000 Cartridges 9 47 13 230/460 60 16
Model Length (in) Height (in) Width (in) Weight (lbs)
Iperjet DF TOWER 10000 55.9 132.3 78 2646
Iperjet DF TOWER 15000 55.9 132.3 78 3087
Iperjet DF TOWER 20000 76.8 144.8 81.9 3307

Our

Resources

FAQ

Iperjet DF TOWER Questions

The Iperjet DF TOWER is a free-standing air purification tower that filters the air of the whole room. It is built for workshops where local or source exhaust is difficult or not possible, where ductwork is complicated or not suitable, or where the source of fumes changes with the process.

Polluted, warm air rises and is drawn in at the top inlet. High-efficiency Class M filter cartridges remove up to 99.9% of dust particles, and the clean air is returned through low outlet diffusers. This creates an upward flow of clean air, with layered ventilation zones that give workers a filtered breathing zone. Optional HEPA H13 post filters remove up to 99.95% of pollutants down to 0.3 microns.

Three models: the TOWER 10000 with 6 cartridges (5,880 CFM, 8 HP, 66 dB(A)), the TOWER 15000 with 9 cartridges (8,820 CFM, 11 HP, 68 dB(A)) and the TOWER 20000 with 9 cartridges (11,760 CFM, 15 HP, 72 dB(A)).

Yes. Because it filters and recirculates the indoor air, the plant no longer has to exhaust its heated or air-conditioned air outdoors. Depending on location and climate, that can save up to 70% of those energy costs.

It is a plug & play installation that needs only a compressed-air connection and electric power, with no piping or ductwork. The tower has lifting eyelets and forklift points, can be moved to another location when needed, empties into a dust container on wheels and is operated from a touchscreen control panel.