ENGINEERED FOR THE FACILITIES THAT CAN'T AFFORD TO STOP
IDROMIX filters with water rather than media, which is why it is the unit specified for explosive metal dust from sanding and grinding. Dusty air mixes with water on entry, centrifugal force separates the heavier particles as sludge into the collection tank, and a droplet separator removes water carried by the purified air before release.
Water consumption is minimal, because only the portion that evaporates during the process needs replenishing, and level probes handle that automatically. The control panel monitors the pressure difference between the dirty and clean sections with minimum and maximum alarms: low water on one side, blockage from accumulated deposits on the other.
Water usage is optimized, as only the portion that evaporates during the process needs to be replenished. Dedicated inspection doors provide easy access for maintenance for the filter bottom, where residual sludge may accumulate.
The electrical control panel monitors the pressure difference between the contaminated air section and the clean air section, with both minimum and maximum alarms. The minimum alarm alerts when the water level in the filter is low, indicating the need for a refill to prevent increased dust emissions. The maximum alarm, on the other hand, warns of excessive blockage in the airlock due to accumulated residues and deposits.
Water is the primary medium used for both dust removal and air purification, as it mixes directly with the contaminated airflow. Centrifugal force causes the heavier particles (sludge) to separate and settle into the collection tank. The CORAL IDROMIX proprietary droplet separator ensures that any water droplets entrained in the purified air are removed before discharge. The water level inside the wet dust collector is monitored by a minimum-level electrical probe, which automatically activates replenishment when the level drops below the set point, and by a maximum-level probe that maintains the water at its optimal operating level.
The CORAL IDROMIX Wet Dust Collector is a wet filtration system designed to remove suspended solid particles from the air. The CORAL IDROMIX Wet is an ideal solution for extracting dust generated during sanding and grinding processes.
Applications: Explosive Metal Dust | Grinding | Sanding.
Water level is part of the filtration stage, since a low level raises emissions: the minimum alarm alerts when the water level in the filter is low, indicating the need for a refill to prevent increased dust emissions. The minimum-level probe triggers automatic replenishment below the set point; the maximum-level probe holds the optimal operating level.
Monitoring: the electrical control panel monitors the pressure difference between the contaminated air section and the clean air section, with both minimum and maximum alarms.
No filter media to clean or replace; maintenance covers sludge and water handling:
For complete specifications, dimensions and options, see the Idromix Wet Dust Collector technical sheet.
| Specification | Value |
|---|---|
| Working static pressure | 14 in w.g. |
| Pressure drop | 8 in w.g. |
| Working temperature | 35.6–140 °F |
| Fan power supply | 230/460 V, 60 Hz, UL |
| Model | Air flow (CFM) | Motor power (HP) |
|---|---|---|
| IDROMIX 2360 | 2360 | 10 |
| IDROMIX 3540 | 3540 | 15 |
| IDROMIX 4710 | 4710 | 20 |
| IDROMIX 5890 | 5890 | 20 |
| IDROMIX 7070 | 7070 | 30 |
| Model | Length (in) | Width (in) | Height (in) | Inlet (in) | Outlet (in) |
|---|---|---|---|---|---|
| IDROMIX 2360 | 63.2 | 97.4 | 125.2 | 11.9 x 11.9 | 8.8 x 12.4 |
| IDROMIX 3540 | 76.9 | 100.8 | 125.2 | 11.9 x 17.7 | 11.3 x 15.9 |
| IDROMIX 4710 | 96.5 | 100.8 | 125.2 | 11.9 x 23.6 | 10.1 x 14.2 |
| IDROMIX 5890 | 106.8 | 100.8 | 125.2 | 11.9 x 27.6 | 12.7 x 17.8 |
| IDROMIX 7070 | 124.5 | 102.8 | 125.2 | 11.9 x 33.5 | 11.3 x 15.9 |
Our
Because the dust it is specified for is explosive. Wet filtration removes the ignition path that a dry cartridge presents, which is why the Idromix is the unit for explosive metal dust from sanding and grinding.
Dusty air mixes with water on entry. Centrifugal force separates the heavier particles as sludge into the collection tank, and a droplet separator removes the water carried by the purified air before release.
Only the portion that evaporates during the process needs replenishing, so consumption is minimal. Level probes handle top up automatically once the level drops below the set point.
The control panel monitors the pressure difference between the dirty and clean sections with minimum and maximum alarms. The minimum alarm signals low water; the maximum alarm signals blockage from accumulated residues and deposits.
Sludge removal and periodic inspection. Dedicated inspection doors give access to the filter bottom where residual sludge accumulates, and an optional discharge for recovered sludge is available.
Fill out the form below and write us about your filtration challenge. We’ll get back to you within 24h.