0%

CORAL

ENGINEERED FOR THE FACILITIES THAT CAN'T AFFORD TO STOP

Idromix Wet Dust Collector

Idromix Wet Dust Collector
Wet Dust Collector, for grinding and sanding operations.

Idromix Wet Dust Collector

Purify Air from Suspended Solid Particles.

IDROMIX filters with water rather than media, which is why it is the unit specified for explosive metal dust from sanding and grinding. Dusty air mixes with water on entry, centrifugal force separates the heavier particles as sludge into the collection tank, and a droplet separator removes water carried by the purified air before release.

Water consumption is minimal, because only the portion that evaporates during the process needs replenishing, and level probes handle that automatically. The control panel monitors the pressure difference between the dirty and clean sections with minimum and maximum alarms: low water on one side, blockage from accumulated deposits on the other.

  • Easy maintenance thanks to special inspection doors
  • Differential pressure control via electrical panel
  • Minimum/Maximum electrical probe to ensure optimal water level
  • Minimized water consumption
  • High efficiency and small footprint
Grinding application

Grinding

Sanding application

Sanding

Hazardous Dust application

Hazardous Dust

Minimal water consumption and easy maintenance

Water usage is optimized, as only the portion that evaporates during the process needs to be replenished. Dedicated inspection doors provide easy access for maintenance for the filter bottom, where residual sludge may accumulate.

Differential Pressure Monitoring System

The electrical control panel monitors the pressure difference between the contaminated air section and the clean air section, with both minimum and maximum alarms. The minimum alarm alerts when the water level in the filter is low, indicating the need for a refill to prevent increased dust emissions. The maximum alarm, on the other hand, warns of excessive blockage in the airlock due to accumulated residues and deposits.

Standard equipment

  • Level probes for water level adjustment
  • Butterfly valve
  • Drop separator
  • Fan
  • Damping bituminous paint on internal surfaces and powder finish on external surfaces

Optional equipment

  • Discharge for recovered sludge
  • Electrical resistors

How it Works

Operating principle

Water is the primary medium used for both dust removal and air purification, as it mixes directly with the contaminated airflow. Centrifugal force causes the heavier particles (sludge) to separate and settle into the collection tank. The CORAL IDROMIX proprietary droplet separator ensures that any water droplets entrained in the purified air are removed before discharge. The water level inside the wet dust collector is monitored by a minimum-level electrical probe, which automatically activates replenishment when the level drops below the set point, and by a maximum-level probe that maintains the water at its optimal operating level.

The CORAL IDROMIX Wet Dust Collector is a wet filtration system designed to remove suspended solid particles from the air. The CORAL IDROMIX Wet is an ideal solution for extracting dust generated during sanding and grinding processes.

Applications: Explosive Metal Dust | Grinding | Sanding.

Airflow Path

  • Contaminated air inlet
  • Water contact: water, the primary medium used for both dust removal and air purification, mixes directly with the contaminated airflow
  • Centrifugal separation: heavier particles (sludge) separate and settle into the collection tank
  • Proprietary droplet separator: entrained water droplets removed from the purified air
  • Fan
  • Discharge of the purified air

Filtration stages

  • Stage 1 – Water contact: water is the primary medium used for both dust removal and air purification, as it mixes directly with the contaminated airflow.
  • Stage 2 – Centrifugal separation into the collection tank: centrifugal force causes the heavier particles (sludge) to separate and settle into the collection tank.
  • Stage 3 – Droplet separator: the CORAL IDROMIX proprietary droplet separator ensures that any water droplets entrained in the purified air are removed before discharge.

Water level is part of the filtration stage, since a low level raises emissions: the minimum alarm alerts when the water level in the filter is low, indicating the need for a refill to prevent increased dust emissions. The minimum-level probe triggers automatic replenishment below the set point; the maximum-level probe holds the optimal operating level.

Monitoring: the electrical control panel monitors the pressure difference between the contaminated air section and the clean air section, with both minimum and maximum alarms.

Cleaning system

No filter media to clean or replace; maintenance covers sludge and water handling:

  • Sludge settles in the collection tank by centrifugal force. Dedicated inspection doors provide easy access for maintenance for the filter bottom, where residual sludge may accumulate.
  • Water make-up is automatic: water usage is optimized, as only the portion that evaporates during the process needs to be replenished.
  • Blockage warning: the maximum alarm warns of excessive blockage in the airlock due to accumulated residues and deposits.
  • Standard components: butterfly valve, drop separator, fan; damping bituminous paint on internal surfaces, powder finish on external surfaces.

For complete specifications, dimensions and options, see the Idromix Wet Dust Collector technical sheet.

Technical Table

General specifications

Specification Value
Working static pressure 14 in w.g.
Pressure drop 8 in w.g.
Working temperature 35.6–140 °F
Fan power supply 230/460 V, 60 Hz, UL

Performance

Model Air flow (CFM) Motor power (HP)
IDROMIX 2360 2360 10
IDROMIX 3540 3540 15
IDROMIX 4710 4710 20
IDROMIX 5890 5890 20
IDROMIX 7070 7070 30
Model Length (in) Width (in) Height (in) Inlet (in) Outlet (in)
IDROMIX 2360 63.2 97.4 125.2 11.9 x 11.9 8.8 x 12.4
IDROMIX 3540 76.9 100.8 125.2 11.9 x 17.7 11.3 x 15.9
IDROMIX 4710 96.5 100.8 125.2 11.9 x 23.6 10.1 x 14.2
IDROMIX 5890 106.8 100.8 125.2 11.9 x 27.6 12.7 x 17.8
IDROMIX 7070 124.5 102.8 125.2 11.9 x 33.5 11.3 x 15.9

Our

Resources

FAQ

Idromix Wet Dust Collector Questions

Because the dust it is specified for is explosive. Wet filtration removes the ignition path that a dry cartridge presents, which is why the Idromix is the unit for explosive metal dust from sanding and grinding.

Dusty air mixes with water on entry. Centrifugal force separates the heavier particles as sludge into the collection tank, and a droplet separator removes the water carried by the purified air before release.

Only the portion that evaporates during the process needs replenishing, so consumption is minimal. Level probes handle top up automatically once the level drops below the set point.

The control panel monitors the pressure difference between the dirty and clean sections with minimum and maximum alarms. The minimum alarm signals low water; the maximum alarm signals blockage from accumulated residues and deposits.

Sludge removal and periodic inspection. Dedicated inspection doors give access to the filter bottom where residual sludge accumulates, and an optional discharge for recovered sludge is available.

Search products

Fill out the form below and write us about your filtration challenge. We’ll get back to you within 24h.