0%

CORAL

ENGINEERED FOR THE FACILITIES THAT CAN'T AFFORD TO STOP

Evolution No-Smoke Extraction Arm

Evolution No-Smoke Extraction Arm
Fume & Dust extraction arm.

Evolution No-Smoke Extraction Arm

Efficiently free your workplace from hazardous substances.

The Coral EVOLUTION NO-SMOKE is the heavy-duty arm in our range, specified where a single workstation produces a demanding contaminant load for a full shift. It handles welding smoke, gas, vapors, aerosol, oil fumes and dust, and stays in service through grinding, deburring, polishing, sanding, thermal cutting, sandblasting and powder coating.

Air captured by the fully articulated hood travels through sheet metal piping to a high efficiency collector or to the plant’s centralized ductwork. Because the arm carries no internal joints, pressure losses stay low, so the same duty can often be met with a smaller fan, lower air speed and less noise at the bench.

  • Patented external articulated joints, for lower pressure losses
  • Up to 30% greater capture efficiency, thanks to its new Winghood hood
  • Quick and easy movements, with up to 360° rotation
  • The toughest on the market, designed for heavy-duty applications
  • 30% energy saving for the same air flow
Welding application

Welding

Grinding application

Grinding

Deburring application

Deburring

Polishing application

Polishing

Sanding application

Sanding

Thermal Cutting application

Thermal Cutting

Dry Dust application

Dry Dust

Hazardous Dust application

Hazardous Dust

Sandblasting application

Sandblasting

Powder Coating application

Powder Coating

The easiest to move extraction arm that will last years.

The unique design and construction features of the patented Coral EVOLUTION NO-SMOKE are coupled together by special external articulated joints that allow for quick and easy movement not offered by other lower cost brands. The completely balanced and easy to operate design is unique and the durable construction will provide many years of reliable and trouble-free operation.

The Coral EVOLUTION NO-SMOKE arm is equipped with a metallic rotary bearing which enables rotation through a full 360°, if installed on its special stand. The flow of polluted air flows undisturbed through the suction arm and is not hindered by internal joints found on competitive models. Due to the reduced length of the hose used in the elbows, pressure losses are far lower than that of other similar systems on the market.

Furthermore, by offering less restriction in the air flow and lower suction load losses, the installation site can install smaller motors on fans which allows for energy savings, lower air flow speed, which equals less noise.

360° rotation, no internal joints and lower pressure losses.

How it Works

Operating principle

The contaminated air is drawn in through the articulated hood, passes through heavy-duty, scratch-resistant painted steel piping (with aluminum or stainless steel as optional), then reaches the high-efficiency fan or the centralized ductwork, and from there to the filtration unit suited for the application.

The Evolution’s piping and hood are linked by patented external articulated joints and durable flexible hose, ensuring smooth and easy arm movement. The system also features a slewing ring that allows full 360° rotation when mounted on the prepared support.

Since airflow is never blocked by internal joints, and thanks to the short hose length at the elbows, pressure drop is much lower than in comparable systems. Lower pressure drop means reduced fan power demand – and therefore energy savings – together with lower air velocity and, as a result, reduced noise levels.

Its patented external articulated joints, fully balanced design, and hand-assembled metallic swivel allow effortless positioning and full 360° rotation. Unobstructed airflow reduces pressure losses, fan load, and noise, ensuring years of reliable, energy-efficient operation.

Airflow path

  • Winghood plastic hood with built-in regulation damper (capture point; damper sets the required airflow)
  • No Smoke Flex flexible hose at the elbows (short lengths; patented external articulated joints keep the bore clear)
  • Rigid pipe: heavy-gauge, scratch-resistant painted steel; aluminum or stainless steel optional
  • Arm slewing ring at the base (full 360° rotation on the prepared support)
  • Junction to either a No Smoke fan (Version with fan: Ø6.3 in at 1.5 HP, Ø8 in at 2.0 HP) or to centralized ductwork
  • Filtration unit suited to the application (not part of the arm)

Components: arm slewing ring for Evolution No Smoke; No Smoke Flex flexible hose; articulated support; rigid pipe; Winghood plastic hood with adjustment damper; junction.

Flow data: recommended nominal flow at 4,130 ft/min air velocity is 353 CFM (Ø4 in), 883 CFM (Ø6.3 in), 1,413 CFM (Ø8 in), 2,178 CFM (Ø10 in); maximum flow at 4,920 ft/min is 418 / 1,060 / 1,678 / 2,602 CFM.

Filtration stages

None on the arm: it delivers the air to the filtration unit suited for the application.

A version with cartridge filter, the self-contained Evolution No Smoke CF, is available in Ø4 in 9 ft and Ø6.3 in 7 | 10 | 14 ft.

Optional hoods with integrated light and spark-arrestor mesh protect the downstream filter from sparks.

Cleaning system

Not applicable: the arm has no filter to clean. The only airflow control is the built-in regulation damper in the hood.

For complete specifications, dimensions and options, see the Evolution No-Smoke Extraction Arm technical sheet.

Technical Table

Model Version Finishing Hood
Evolution NO-SMOKE Ø 100/2,7 Wall Pre-painted, Stainless Steel Aluminum
Evolution NO-SMOKE Ø 100/2,7 Portable Pre-painted, Stainless steel –
Evolution NO-SMOKE Ø 160/2 Wall Pre-painted, Stainless steel Winghood
Evolution NO-SMOKE Ø 160/3 Portable Pre-painted, Stainless steel Winghood
Evolution NO-SMOKE Ø 160/3 Wall Pre-painted, Stainless steel Winghood
Evolution NO-SMOKE Ø 160/4 Wall Pre-painted, Stainless steel Winghood
Evolution NO-SMOKE Ø 200/2 Wall Aluminum Aluminum
Evolution NO SMOKE Ø 200/3 Wall Aluminum Aluminum
Evolution NO-SMOKE Ø 200/3 Portable Aluminum Aluminum
Evolution NO-SMOKE Ø 200/4 Wall Aluminum Aluminum
Evolution NO-SMOKE Ø 250/3 Wall Aluminum –
Evolution NO-SMOKE Ø 250/3 Portable Aluminum Aluminum
Evolution NO-SMOKE Ø 250/4 Wall Aluminum –
Model Diameter (in) Length (in) Working position A (in) Working position B (in) Working position C (in) Working position D (°) Working position E (°) Open arm A (in) Open arm B (in) Open arm C (in) Open arm D (°) Open arm E (°) Closed arm A (in) Closed arm B (in) Closed arm C (in) Closed arm D Closed arm E Closed arm F (in)
Evolution NO-SMOKE Ø 100/2,7 4 107 87 118 59 110° 100° 87 118 47 145° 78° 24 118 83 10° 155° 32
Evolution NO-SMOKE Ø 100/2,7 4 107 71 – – 90° 135° 91 – – 180° 90° 15 – – 0° 180° –
Evolution NO-SMOKE Ø 160/2 6,3 – – – – 145° 80° 111 – – 180° 90° – – – 10° 150° –
Evolution NO-SMOKE Ø 160/3 6,3 119 89 – – 90° 135° 102 – – 180° 90° 25 – – 0° 180° –
Evolution NO-SMOKE Ø 160/3 6,3 119 96 118 55 145° 80° 110 118 91 180° 90° 35 118 83 10° 150° 34
Evolution NO-SMOKE Ø 160/4 6,3 158 130 118 79 110° 120° 142 118 59 150° 90° 39 118 83 10° 150° 55
Evolution NO-SMOKE Ø 200/2 8 – – – – 140° 80° 103 – – 180° 90° – – – 10° 150° –
Evolution NO SMOKE Ø 200/3 8 119 93 118 47 140° 80° 102 118 87 180° 90° 32 118 78 10° 150° 35
Evolution NO-SMOKE Ø 200/3 8 119 89 – – 90° 135° 102 – – 180° 90° 28 – – 0° 180° –
Evolution NO-SMOKE Ø 200/4 8 158 126 118 55 115° 105° 147 118 88 180° 90° 39 118 79 10° 155° 57
Evolution NO-SMOKE Ø 250/3 10 119 96 118 51 130° 110° 102 118 88 180° 90° 32 118 75 15° 165° 37
Evolution NO-SMOKE Ø 250/3 10 119 91 – – 90° 135° 104 – – 180° 90° 30 – – 0° 180° –
Evolution NO-SMOKE Ø 250/4 10 158 132 118 59 110° 100° 148 118 89 180° 90° 39 – 77 15° 165° 59

Our

Resources

FAQ

Evolution No-Smoke Extraction Arm Questions

Welding smoke, gases, vapors, aerosols, oil fumes and dust. It stays in service through grinding, deburring, polishing, sanding, thermal cutting, sandblasting and powder coating, which is why it is specified for stations that carry a demanding contaminant load for a full shift rather than in short bursts.

Four hood diameters, 4, 6.3, 8 and 10 inches, in reach lengths of 7 to 14 feet. Wall mounted and portable versions are both published, and the finish is aluminum, pre-painted or stainless steel depending on the model.

Internal joints are where pressure is lost. Removing them keeps losses low across the whole run, so the same capture duty can often be met with a smaller fan, a lower air speed and noticeably less noise at the bench.

Yes. The arm is a capture device, and air travels through sheet metal piping to a high efficiency collector or into the plant’s centralized ductwork. Where there is no collector and no ducting, specify the self-contained CF version instead, which packages the arm, fan and cartridge filter into one unit.

Not the standard build. For a zone classified as potentially explosive, specify the Evolution No-Smoke ATEX arm, whose construction materials guarantee a ground connection and dissipate the static charge that airflow generates inside the pipes.

Search products

Fill out the form below and write us about your filtration challenge. We’ll get back to you within 24h.