Evolution No-Smoke Extraction Arm

Fume & Dust extraction arm.

Efficiently free your workplace from hazardous substances.

The Coral EVOLUTION NO-SMOKE self-supporting suction arm represents the best possible solution for the removal of welding smoke, gas, vapors, aerosol, oil fumes, dust, etc. directly at the source.

Coral has specifically designed the EVOLUTION NO-SMOKE extraction arm to be in full compliance with all standards regarding safety in the workplace for the removal of hazardous fumes and polluting substances from the working environment.

  • Patented external articulated joints, for lower pressure losses
  • 30% greater suction efficiency, thanks to its new Winghood hood
  • Quick and easy movements, with up to 360° rotation
  • The toughest on the market, designed for heavy-duty applications
  • 30% energy saving for the same air flow

  • Welding
  • Grinding
  • Deburring
  • Polishing
  • Sanding
  • Thermal Cutting
  • Dry Dust
  • Hazardous Dust
  • Sandblasting
  • Powder Coating
  • Welding
  • Grinding
  • Deburring
  • Polishing
  • Sanding
  • Thermal Cutting
  • Dry Dust
  • Hazardous Dust
  • Sandblasting
  • Powder Coating

Technical table

Model Version Finishing Hood
Evolution NO-SMOKE Ø 100/2,7 Wall Aluminum, Pre-painted, Stainless Steel Aluminum
Evolution NO-SMOKE Ø 100/2,7 Portable Aluminum, Pre-painted, Stainless steel -
Evolution NO-SMOKE Ø 160/2 Wall Pre-painted Winghood
Evolution NO-SMOKE Ø 160/3 Portable Pre-painted Winghood
Evolution NO-SMOKE Ø 160/3 Wall Pre-painted Winghood
Evolution NO-SMOKE Ø 160/4 Wall Pre-painted Winghood
Evolution NO-SMOKE Ø 200/2 Wall Aluminum Aluminum
Evolution NO SMOKE Ø 200/3 Wall Aluminum Aluminum
Evolution NO-SMOKE Ø 200/3 Portable Aluminum Aluminum
Evolution NO-SMOKE Ø 200/4 Wall Aluminum Aluminum
Evolution NO-SMOKE Ø 250/3 Wall Aluminum -
Evolution NO-SMOKE Ø 250/3 Portable Aluminum Aluminum
Evolution NO-SMOKE Ø 250/4 Wall Aluminum -
Model Diameter (in) Lenght (in) Working position A (in) Working position B (in) Working position C (in) Working position D (°) Working position E (°) Open arm A (in) Open arm B (in) Open arm C (in) Open arm D (°) Open arm E (°) Closed arm A (in) Closed arm B (in) Closed arm C (in) Closed arm D Closed arm E Closed arm F (in)
Evolution NO-SMOKE Ø 100/2,7 4 107 87 119 60 110° 100° 87 119 48 145° 78° 24 119 83 10° 155° 32
Evolution NO-SMOKE Ø 100/2,7 4 107 71 - - 90° 135° 91 - - 180° 90° 15 - - 180° -
Evolution NO-SMOKE Ø 160/2 6,3 - - - - 145° 80° 111 - - 180° 90° - - - 10° 150° -
Evolution NO-SMOKE Ø 160/3 6,3 119 89 - - 90° 135° 103 - - 180° 90° 26 - - 180° -
Evolution NO-SMOKE Ø 160/3 6,3 119 97 119 56 145° 80° 111 119 91 180° 90° 36 119 83 10° 150° 34
Evolution NO-SMOKE Ø 160/4 6,3 158 130 119 79 110° 120° 142 119 60 150° 90° 40 119 83 10° 150° 56
Evolution NO-SMOKE Ø 200/2 8 - - - - 140° 80° 103 - - 180° 90° - - - 10° 150° -
Evolution NO SMOKE Ø 200/3 8 119 94 119 48 140° 80° 103 119 87 180° 90° 32 119 78 10° 150° 36
Evolution NO-SMOKE Ø 200/3 8 119 89 - - 90° 135° 103 - - 180° 90° 28 - - 180° -
Evolution NO-SMOKE Ø 200/4 8 158 126 119 56 115° 105° 147 119 88 180° 90° 40 119 79 10° 155° 58
Evolution NO-SMOKE Ø 250/3 10 119 97 119 52 130° 110° 103 119 88 180° 90° 32 119 75 15° 165° 38
Evolution NO-SMOKE Ø 250/3 10 119 91 - - 90° 135° 105 - - 180° 90° 30 - - 180° -
Evolution NO-SMOKE Ø 250/4 10 158 132 119 60 110° 100° 148 119 89 180° 90° 40 - 77 15° 165° 60